Zum Inhalt springen
Produkte

// Benutzung · Steuerung

Power-cycling a server via iDRAC

Power a physical server on or off, or reset it, from the admin UI — through its iDRAC/Redfish BMC. Like all control actions it runs on the location's agent and is written to the hub-wide audit log (control.* rows: a proposed row before it runs, and how it ended).

These are hardware power actions on a real server. Force Off and Power Cycle cut power immediately (no graceful OS shutdown). Requires the control.execute permission (admin).

Doing it

  1. Open the location → Resources tab.

  2. On the registered iDRAC host card, use the Power buttons:

    Button What it does Redfish ResetType
    Power On Turn the server on On
    Graceful Shutdown Ask the OS to shut down cleanly GracefulShutdown
    Force Off Cut power immediately ForceOff
    Reset Hard reset ForceRestart
    Power Cycle Off, then on PowerCycle
  3. Confirm in the dialog (it names the host). Everything but Power On is treated as destructive and gets the red confirm.

Buttons are disabled while the agent is unreachable. The action targets the iDRAC host resource, whose stored credential (username/password) the agent reveals to authenticate to the BMC.

Verifying

The result appears in the Agents tab → Control path audit log (the control rows of the audit log; all of it on the Audit page with audit.view), and the server's power draw / state updates on the next agent report (nudged automatically after the action). If a BMC uses a self-signed certificate, the resource must have Allow invalid/self-signed TLS certificates ticked (see Adding a resource to a location), or the action fails on cert verification.

// Zusammenarbeit

Bereit, Ihre digitale Infrastruktur zu bauen?

Ob individuelle Automatisierung für Ihr Unternehmen oder ein durchgeplantes Netzwerk für Ihr Zuhause — lassen Sie uns über das Projekt sprechen.